BZNQD - VACTRA OIL NO. 2

  • MSDS: BZNQD
  • Manufacturer: MOBIL OIL CORP
  • Product Name: VACTRA OIL NO. 2
  • National Stock Number: 9150-00-045-4317
Product Identification

Product ID:VACTRA OIL NO. 2
MSDS Date:08/22/1995
FSC:9150
NIIN:00-045-4317
MSDS Number: BZNQD

Responsible Party
MOBIL OIL CORP
3225 GALLONS ROAD
FAIRFAX, VA 22037-0001
US

Emergency Phone: 609-737-4411/CHEMTREC 800-424-9300

Info Phone: 800-662-4525/800-227-0707 X3265

Preparer: MOBIL OIL CORPORATION

Cage: 1E969

Contractor
MOBIL OIL CORP, NORTH AMERICAS MARKETING AND REFINING
FAIRFAX, VA 22037 US

Telephone: 800-662-4525/ 856-224-4644

Cage: 3U728

Ingredients

BARIUM (SARA 313) (BY TCLP)

CAS: 7440-39-3

RTECS: CQ8370000

Fraction By Weight: 0.0230%

OSHA PEL 0.5 MG/M3


TRICRESYLPHOSPHATE; PHOSPHORIC ACID, TRIS(METHYLPHENYL)

CAS: 1330-78-5

RTECS: TD0175000

Fraction By Weight: 0.02%


SEE CONTAINER LABEL FOR INGREDIENT INFORMATION.


PRODUCT ASSESSED IAW OSHA 29 CFR 1910.1200 & DETERMINED NOT

Hazards

LD50 LC50 Mixture:ORAL LD50 RAT>2000MG/KG SIMILAR PROD/ING
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO SIGNIFICANT EFFECTS EXPECTED.
PRACTICALLY NON-TOXIC, NON EYE IRRIT, NON SKIN IRRIT BASED ON
TESTING OF SIMILAR PRODUCTS &/OR THE COMPONENTS. TLV 5.00 MG/M3
SUGGESTED FOR OIL MIST.
Explanation of Carcinogenicity:BASE OIL IN PROD SEVER SOLVT REFINED
&/OR SEVER HYDROTREAT.CHRONIC MOUSE SKIN PAINT STUDIES SHOW NO
EVIDENCE OF CARC EFF
Effects of Overexposure:NO SIGNIFICANT EFFECTS EXPECTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH THOROUGHLY W/WTER.IRRIT OCCURS CALL PHYSICIAN.
SKIN:WASH AREA W/SOAP/WATER. INHAL:REMOVE FROM FURTHER EXPO.RESP
IRRIT/DIZZ/NAU/UNCONSC OCCUR SEEK IMMED MED ASSIST/CALL
PHYSICIAN.BREATH STOP SUE MOUTH-TO-MOUTH RESUSC. INGEST:NOT
EXPECTED TO BE PROBLEM WHEN INGEST.IF UNCOMFORTABLE SEEK MED
ASSIST.

Fire Fighting

Flash Point Method:COC
Flash Point:>399F,>204C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:H2O/FOAM MAY CAUSE FROTH.COOL FIRE-EXPO CNTNR
W/H2O.FLUSH SPILL AWAY FRM EXPO W/H2OSPRAY.PREVENT RUNOFF FRM FIRE
CNTRL/DIL ENTER STREAM/SEWERS/DRINK H2O (SUPPL)
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:REPORT AS REQUIRED TO APPROP AUTHOR.SPILL
REACH WATERSAY(INCLUDING INTERMITTENT DRY CREEKS)CALL COAST GUARD
800-424-8802.ABSORB ON FIRE RETARDANT TREATED SAWDUST/DIATOMACEIOUS
EARTH/ETC.SHOVELUP/DISPO .PREVENT ENTERING STORM
SEWERS/DRAN/CONTACT SOIL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE IN OPN/UNLABEL
CNTNRS.STORE AWAY FROM STRONG OXIDIZING AGENTS/COMBUST MATL.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NO SPECIAL REQIREMENTS UNDER ORDINARY CONDITIONS
OF USE & W/ADEQUATE VENTILATION.
Ventilation:USE IN WELL VENTILATED AREA.
Protective Gloves:FOLLOW GOOD PERSAL HYGIENE PRACTICES.
Eye Protection:NORMAL INDUSTRIAL EYE PROT PRACTICES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NORMAL GOOD HYGIENE PRACTICES.
Supplemental Safety and Health
FIREFIGHTING:FIRES IN ENCLSD AREAS FIREFIGHTERS MUST USE SCBA.
DISPO:W/APPLICABLE LAWS/REGS/CONSIDERATION OF PROD CHARACTERISTICS
@DISPO TIME.UNUSED PROD SUBJ TO RCRA REGS DUE TO BARIUM
PRESENT(0.0230 %)(TCLP).DISPO OF USED PROD MAY BE REG DUE
IGN/CORR/RACT/TOX PER TCLP.SARA 313 REPORTABLE:NONE.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:>601F,>316C
Vapor Pres:<0.1 @20C
Vapor Density:>2.0
Spec Gravity:0.879
Viscosity:>63.2CST @40C
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIQUID, BROWN COLOR, MILD ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:PHOSPHORUS OXIDES, SULFUR OXIDES,
CARBON MONOXIDE.

Disposal

Waste Disposal Methods:PROD SUITABLE FOR BURN IN ENCLSD/CNTRL BURNER
FOR FUEL VAL/DISPO BY SUPERVISED INCINERATION(LIMITED PURSUANT TO
RCRA).PROD SUITABLE FOR PROCESSING BY APPROVED RECYCL FAC/DISPO
@GOVT APPROVED WASTE DIS PO FACIL.ALL METHODS SUBJ TO
COMPLIANCE(SUPPLEME)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.